Caddy Advanced Hot Air Wood Furnace
By Caddy
$4,594.38
- SKU:
- PF01020
- Width:
- 28.00 (in)
- Height:
- 41.00 (in)
- Depth:
- 42.00 (in)
- Shipping:
- Calculated at Checkout
Financing Available!
***Only available in Canada***
THE NEW GENERATION OF FURNACES
Known for its exceptional performance, the Caddy Advanced is a furnace that’s innovative design (patent pending) is surpassed only by its simplicity of use.
DISCOVER SELF-REGULATED COMBUSTION
The self-regulated combustion of the Caddy Advanced promises constant heat, while requiring minimal effort on your part; just fill the furnace, adjust the temperature and enjoy the heat for hours! The system automatically adjusts the air supply so that combustion is optimized and synchronized with the thermostatic demand.
- At start-up, the furnace injects additional combustion air for easy and quick ignition.
- As the furnace goes into heating mode, it automatically adjusts the combustion air supply and the operation of the convection blower. When your home’s desired temperature is reached (thermostat setting), the furnace goes into energy saving mode, automatically reducing the combustion air and speed of the convection blower.
- At the end of the combustion cycle, if the furnace needs to go back to heating mode (thermostat setting), additional combustion air is injected again to activate the combustion of the embers thus providing a hotter burn on the end of the combustion cycle.
EASE OF USE
Use the Caddy Advanced with confidence thanks to its intuitive operation and illustrated quick user guide. Equipped with a glass door allowing you to easily monitor the state of combustion, the furnace optimizes its combustion cycle: you will spend much less time taking care of it vs a conventional furnace (loading wood, adjusting the air, etc.). This optimization also ensures you substantial savings in firewood as well as increased comfort thanks to the production of constant heat throughout the combustion cycle.
UNMATCHED PERFORMANCE
Among the most efficient furnaces in terms of energy distribution, the Caddy Advanced has one of the lowest minimum burn rates in the industry. This means a load of wood burns longer, and therefore reduces the frequency of wood loading. Emissions on this unit are amongst the cleanest of the few EPA 2020 certified furnaces, and yet the Caddy Advanced is among the most energy efficient on the market. In addition, the new ECM motor blower option consumes 40% less electricity (and much quieter) than a standard PSC motor blower.
QUICK AND FLEXIBLE INSTALLATION
The Caddy Advanced is equipped with pre-wired electrical components that allow for quick and hassle-free installation. For more flexibility, you can install the filter supports on either sides and on top of the blower box to adapt the layout of the ventilation ducts to your space. In addition, the add-on configuration allows you to install the Caddy Advanced with your existing electric, oil or gas central heating system to take advantage of an alternative energy source.
The Caddy Advanced includes a tool set and wall support, an ash lip, a thermostat, a moisture reader, a barometric damper and a fresh air intake adapter.
Alternate source of heat
Always have an alternate source of heat to ensure the comfort and safety of your family. The Caddy Advanced comes in two different configurations: wood-only and wood add-on furnace.
When installed as an add-on furnace, only a SERIES configuration is allowed only in Canada and the blower is not required. | Only PARALLEL configuration is allowed in the USA.
Appliance performance (2)
Fuel type | Dry cordwood (16" recommended) | |
Recommended heating area-ft² () | 1,000 - 2,500 | |
Overall firebox volume-ft³ | 3.6 | |
Maximum burn time () | 10 h | |
Maximum input capacity (dry cordwood) (3) | 310,000 BTU | |
Overall heat output rate < (4) | 19,354 BTU/h (5.6 kW) to 47,052 BTU/h (13.8 kW) | |
Average overall efficiency (min. to max.) (5) | 76.6 % (HHV) (6) | 82 % (LHV) (7) |
Delivered heat output rate (min. to max.) (8) | 13,297 BTU/h (3.9 kW) to 42,234 BTU/h (12.4 kW) | |
Average delivered efficiency (min. to max.) (9) | 60.7 % (HHV) (6) | 65 % (LHV) (7) |
Optimum efficiency (10) | 83.2 % | |
Optimum heat transfer efficiency (11) | 81 % | |
Average particulate emissions rate (1) (12) | 0.095 lb/mmBTU (0.041 g/MJ) | |
Average CO (13) | 8.78 lb/mmBTU (3.78 g/MJ) | |
Average electrical power consumption (14) | 220 W | 360 W |
(1) Based on delivered heat output.
(2) Values are as measured per CSA B415.1-10, except for the recommended heating area, firebox volume, maximum burn time and maximum input capacity. Performances based on a fuel load prescribed by the standard at 10 lb/ft³ and with a moisture content between 18% and 28%.
() Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss factors, climate, fuel type and other variables. The recommended heating area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature considering that the space configuration and the presence of heat distribution systems have a significant impact in making heat circulation optimum.
(3) Input value at 10 lb/ft³ fuel loading density and dry energy value of 8,600 BTU/lb.
(4) Overall : Radiated and delivered heat together at 10 lb/ft³ fuel loading density over one total burn cycle.
(5) Efficiency based on radiated and delivered heat when allowing cycling from high to low burn to simulate thermostat demand.
(6) Higher Heating Value of the fuel.
(7) Lower Heating Value of the fuel.
(8) Delivered: Remotely provided to other rooms through ducting at 10 lb/ft³ fuel loading density over one total burn cycle.
(9) Efficiency based on delivered heat when allowing cycling from high to low burn to simulate thermostat demand. LHV % is based on manufacturer’s estimation.
(10) Optimum overall efficiency at a specific burn rate (LHV).
(11) The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
(12) This appliance is officially tested and certified by an independent agency.
(13) Carbon monoxyde.
(14) Unless stated otherwise, measures were taken directly at the main power source and include all electrical components present in the appliance.
General features
High-efficiency certified appliance | Yes, EPA 2020 approved |
Maximum log length | 21" |
Log positioning | Loading over width and over depth |
Chimney diameter | 6" |
Flue outlet diameter | 6" |
Type of chimney | CAN/ULC S629, UL 103 HT (2100 °F) |
Baffle type | C-Cast or equivalent |
Shipping Weight | 705 lb |
Door type | Single, glass with cast iron frame |
Glass type | Ceramic glass |
Glass surface – dimensions (Width X Height) | 12 1/2" X 10 1/8" |
Blower (hp / speed / CFM) | 1/3 / 1 / 875 |
Filter – dimensions (Width X Height X Depth) | 14" X 25" X 1" |
Overall dimension (Height) | 41 3/4" |
Overall dimension (Width) | 28 3/4" |
Overall dimension (Depth) | 42 1/2" |
Door opening – dimension (Height) | 10" |
Door opening - dimension (Width) | 13 3/4" |
Firebox – dimension (Height) | 16 1/8'' |
Firebox – dimension (Width) | 18 3/4'' |
Firebox – dimension (Depth) | 22 1/2'' |
Steel thickness – body | 3/16" |
Steel thickness – top | 1/4" |
Easy-to-access ash drawer | Yes |
Air return plenum – dimension (Depth or Height) | 15 3/4'' |
Air return plenum – dimension (Width) | 24 3/4'' |
Hot air plenum – dimension (Depth or Height) | 28 5/8'' |
Hot air plenum – dimension (Width) | 24 1/2'' |
USA standard (emissions) | EPA |
Canadian Standard (emissions) | CSA B415.1-10 |
USA standard (safety) | UL 391 |
Canadian standard (safety) | CSA B366.1 |
Tested and listed as per applicable standards | By an accredited laboratory (CAN/USA) |
Warranty | Limited lifetime |
Minimum clearances to combustibles* (Data expressed in inches. 1 inch = 25.4 mm) |
||
Canada | United-States | |
Clearance – back wall | 24" | 24" |
Clearance – ducts | <6'=6" ; >6'=1" | <6'=6" ; >6'=1" |
Clearance – top (measured from the platform on which the appliance is installed)** | 67" | 67" |
Clearance – recommended for maintenance on option side | 24" | 24" |
Clearance – front | 48" | 36" |
Clearance - side wall | 24" | 24" |
Clearance – opposite side wall | 6" | 6" |
Clearance – minimum floor protection under the appliance | 37 1/8" | |
* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites). |
||
** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual. |