Adding to cart… The item has been added

â–ªSmall-sized wood insert suitable for tighter spaces
â–ªTapered shape (top and sides) that simplifies installation in small masonry hearths
â–ªEPA certified at only 1.5 g/h
â–ªBest-in-class performance with an efficiency rate of 75%
â–ªSolidity and manufacturing quality
â–ªC-Cast heat shield added to the firestop
â–ªNon-catalytic combustion technology
â–ªInstallation authorized on the Island of Montreal
â–ªCast iron door
â–ª90 CFM blower with right/left powercord

Required option: regular faceplate (VBA1545)

Appliance performance

Fuel type Dry cordwood
Recommended heating area (9) 250 - 1,200 ft²
Overall firebox volume 1.1 ft³
EPA loading volume 1.03 ft³
Maximum burn time (9) 7 h
Maximum heat output-dry cordwood (4) 45,000 BTU/h
Minimum overall heat output rate (4) (5) 8,471 BTU/h (2.48 kW)
Maximum overall heat output rate (4) (5) 31,700 BTU/h (9.29 kW)
Average overall efficiency-dry cordwood (HHV) (5) (6) 75%
Average overall efficiency-dry cordwood (LHV) (5) (7) 80%
Optimum efficiency (1) (2) 82%
Optimum heat transfer efficiency (8) 78%
Average particulate emission rate (3) 1.5 g/h
Average CO (10) 34 g/h
  • 1. Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.
  • 2. Optimum overall efficiency at a specific burn rate (LHV).
  • 3. This appliance is officially tested and certified by an independent agency.
  • 4. The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.
  • 5. As measured per CSA B415.1-10 stack loss method.
  • 6. Higher Heating Value of the fuel.
  • 7. Lower Heating Value of the fuel.
  • 8. The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the solid fuels into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
  • 9. Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
  • 10. Carbon monoxyde.

General features

Mobile home approved No
Premium quality blower included (CFM) 90 CFM included
Certified according to applicable standards CAN/USA accredited laboratory
Combustion technology Non-catalytic
Stainless-steel secondary-air system Yes
Flue outlet diameter 6"
Recommended chimney diameter 6"
Type of chimney ULC-S635, CAN/ULC-S640, UL 1777
Minimum chimney height 12"
Overall dimension (Width) 27 7/8"
Overall dimension (Height) 20 1/8"
Overall dimension (Depth) 20"
Door type Single, glass with cast iron frame
Door opening size (Width) 18 1/4"
Door opening size (Height) 7 7/8"
Glass type Ceramic glass
Glass surface - W x H 17 7/8" x 8"
Steel thickness-body 3/16"
Steel thickness-top 3/16"
Firebox size (Width) 16 3/4"
Firebox size (Height) 8 7/8"
Firebox size (Depth) 12 3/8"
Maximum log length 17" (16" recommended)
Log positioning Loading over width
Firebox lined with refractory bricks Yes
Baffle type C-Cast or equivalent
Minimum fireplace opening (Width) 25"
Minimum fireplace opening (Height) 19"
Minimum fireplace opening (Depth) 15 1/2"
High-efficiency certified appliance Yes, EPA 2020 approved
Canadian Standard (emissions) CSA B415.1-10
USA Standard (emissions) EPA
Canadian Standard (safety) ULC S628
USA Standard (safety) UL 1482, UL 737
Warranty Limited 5 years
Shipping weight 282 lb (kg)

Clearances

Minimum clearances to combustibles*
(Data expressed in inches. 1 inch = 25.4 mm)

  Canada United-States
Clearances - Base of the unit to ceiling** 72" 72"
Clearances - Combustible top mantle to unit 1" 1"
Clearances - Combustible side mantle to unit 1" 1"
Clearances - Combustible side wall to unit 16" 16"
Clearances - Top of the unit to a 12" combustible mantle shelf 34" 34"
 

 