Max Caddy Hot Air Wood Furnace
By Caddy
$4,971.03
- SKU:
- PF01102
- Width:
- 37.00 (in)
- Height:
- 51.00 (in)
- Depth:
- 61.00 (in)
- Shipping:
- Calculated at Checkout
Financing Available!
***Only available in Canada***
Ingenuity 2.0
Thanks to its electronic platform facilitating connections between systems, PSG's largest furnace is the best option for your home heating and air conditioning system.
The power to communicate
Max Caddy’s new streamlined electronic platform makes it easy for different systems to talk to each other. Heat pumps, air conditioners, humidifiers-the Max Caddy easily communicates with all of these appliances using standard industry symbols and practices. Easy-to-identify input and output ports and a blower assembly with prewired main board simplify installation and hookup. And PSG’s touchscreen LCD control module makes input and output control a breeze.
A benchmark for efficiency
The Max Caddy’s integrated control PC board and RTD probe automatically ensures that the furnace blower is operating at optimum speed, keeping the plenum at just the right temperature. The built-in heat exchanger system ensures that heat is transferred quickly and efficiently via the smoke ducts inside the furnace instead of being lost up the chimney. The result is superior comfort and energy efficiency, with savings of up to 30% on firewood.
Multi-energy flexibility and peace of mind
The Max Caddy can be installed as a wood-only unit, but is also available in wood+electric, wood+oil combo, or even wood+oil+electric triple combo configurations so you can heat your home using multiple energy sources. With Caddy series furnaces, you’ll always have an alternate source of heat to ensure the comfort and safety of your family.
Wood
This furnace can be installed as a wood-only unit. Blower box and fan limit kit required for this configuration.
Combined Wood + Electric
This furnace can be installed as a wood+electric combo unit to ensure your central heating keeps running even when you’re not there to add more firewood. Electric element (fan limit kit included) required for this configuration.
Combined Wood + Fuel Oil
This furnace can be installed as a wood+oil combo to ensure your central heating keeps running even when you’re not there to add more firewood. Oil burner unit and blocked vent switch required for this configuration.
Wood Add-on
If you’ve already got an oil, gas, or electric central heating system but want to add the flexibility of wood, the Max Caddy wood add-on furnace is for you. This unit, which installs on either side of your existing system, uses the same controls and fan as your existing furnace, giving you a fully compatible wood+oil, wood+gas, or wood+electric combo system.
Appliance performance (2)
Fuel type | Dry cordwood (16" recommended) | |
Recommended heating area-ft² () | 1,500 - 3,500 | |
Overall firebox volume-ft³ | 4.9 | |
Maximum burn time () | 17 h | |
Maximum input capacity (dry cordwood) (3) | 421,000 BTU | |
Overall heat output rate < (4) | 18,424 BTU/h (5.6 kW) to 66,576 BTU/h (19.6 kW) | |
Average overall efficiency (min. to max.) (5) | 78.90% (HHV) (6) | 85.8% (LHV) (7) |
Delivered heat output rate (min. to max.) (8) | 15,118 BTU/h (4.7 kW) to 51,241 BTU/h (16 kW) | |
Average delivered efficiency (min. to max.) (9) | 64.80% (HHV) (6) | 70.20% (LHV) (7) |
Optimum efficiency (10) | 85.80% | |
Average particulate emissions rate (1) (11) | 0.753 lb/mmBTU (0.326 g/MJ) | |
Average CO (12) | 12.20 lb/mmBTU (5.25 g/MJ) | |
Average electrical power consumption (13) | 360 W |
(1) Based on delivered heat output.
(2) Values are as measured per CSA B415.1-10, except for the recommended heating area, firebox volume, maximum burn time and maximum input capacity. Performances based on a fuel load prescribed by the standard at 10 lb/ft³ and with a moisture content between 18% and 28%.
() Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss factors, climate, fuel type and other variables. The recommended heating area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature considering that the space configuration and the presence of heat distribution systems have a significant impact in making heat circulation optimum.
(3) Input value at 10 lb/ft³ fuel loading density and dry energy value of 8,600 BTU/lb.
(4) Overall : Radiated and delivered heat together at 10 lb/ft³ fuel loading density over one total burn cycle.
(5) Efficiency based on radiated and delivered heat when allowing cycling from high to low burn to simulate thermostat demand.
(6) Higher Heating Value of the fuel.
(7) Lower Heating Value of the fuel.
(8) Delivered: Remotely provided to other rooms through ducting at 10 lb/ft³ fuel loading density over one total burn cycle.
(9) Efficiency based on delivered heat when allowing cycling from high to low burn to simulate thermostat demand. LHV % is based on manufacturer’s estimation.
(10) Optimum overall efficiency at a specific burn rate (LHV).
(11) This appliance is officially tested and certified by an independent agency.
(12) Carbon Monoxyde. Based on overall heat output at 10 lb/ft³ fuel loading density.
(13) Unless stated otherwise, measures were taken directly at the main power source and include all electrical components present in the appliance.
General features
High-efficiency certified appliance | CSA B415.1-10 |
Maximum log length | 25" |
Log positioning | Loading over depth |
Chimney diameter | 6" |
Flue outlet diameter | 6" |
Type of chimney | CAN/ULC S629, UL 103 HT (2100 °F) |
Baffle type | C-Cast or equivalent |
Approved for a mobile home installation | No |
Shipping Weight | 729 lb (331 kg) |
Door type | Single, glass with cast iron frame |
Glass type | Ceramic glass |
Glass surface – dimensions (Width X Height) | 14 1/2" X 10 1/8" |
Glass air-wash system | Yes |
Blower (hp / speed / CFM) | 1/2 / 4 / 2,100 |
Filter – dimensions (Width X Height X Depth) | 16" X 20" X 1" |
Overall dimension (Height) | 50 1/2" |
Overall dimension (Width) | 36 1/4" |
Overall dimension (Depth) | 60 1/8" |
Door opening – dimension (Height) | 9 7/8" |
Door opening - dimension (Width) | 15 3/4" |
Firebox – dimension (Height) | 15 7/8" |
Firebox – dimension (Width) | 20 3/8" |
Firebox – dimension (Depth) | 26 1/4" |
Firebox lined with refractory bricks for better heat distribution | Yes |
Stainless-steel secondary-air system improving gas combustion | Yes |
Adjustable threaded legs | Yes |
Steel thickness – body | 3/16" |
Steel thickness – top | 1/4" |
Easy-to-access ash drawer | Yes |
Air return plenum – dimension (Depth or Height) | 17 7/8" |
Air return plenum – dimension (Width) | 19 7/8" |
Hot air plenum – dimension (Depth or Height) | 32 1/8" |
Hot air plenum – dimension (Width) | 25 3/8" |
Burner – standard | Beckett - AFG |
Burner – other brand approved | Riello |
Burner – location | Right or left |
Burner – efficiency at input #1 | 85 % (Beckett) |
Burner – efficiency at input #2 | 87 % (Riello) |
Burner – recommended connector pipe diameter (Wood-oil) | 7" |
Burner – recommended exhaust pipe diameter | 5" |
Burner – location of exhaust pipe | Right or left |
Burner – capacity at input #1 | 90,000 BTU (26.4 kW) |
Burner – capacity at input #2 | 91,000 BTU (27 kW) |
Burner – orifice at input #1 | 0.55 X 60°W (Beckett) |
Burner – orifice at input #2 | 0.50 X 70°W (Riello) |
Burner – pump pressure at input #1 | 140 psi (Beckett) |
Burner – pump pressure at input #2 | 150 psi / 165 psi |
Electric element – location | Right or left |
Burner – recommended clearance for maintenance | 24" |
Electric element – recommended (maximum output) | 20 kW |
Electric element – other optional (maximum output) | 25 kW |
Water loop kit – connection location | Right or left |
Water loop kit – connecting pipe diameter | 3/4" |
Water loop kit – back-up tank volume | 60 gal (227 L) |
Canadian Standard (emissions) | CSA B415.1-10 |
USA standard (safety) | UL 1995, UL 727, UL 391 |
Canadian standard (safety) | CSA B366.1, CSA C22.2 no 236, CAN/CSA B140.4 CSA B212-93 |
Tested and listed as per applicable standards | By an accredited laboratory (CAN/USA) |
Warranty | Limited lifetime |
Minimum clearances to combustibles* (Data expressed in inches. 1 inch = 25.4 mm) |
||
Canada | United-States | |
Clearance – back wall | 24" | 24" |
Clearance – ducts | <6'=6" + protection ; >6'=1" | <6'=6" + protection ; >6'=1" |
Clearance – recommended for maintenance on option side | 24" | 24" |
Clearance – front | 48" | 48" |
Clearance - side wall | 6" | 6" |
Clearance – opposite side wall | 24" | 24" |
Clearance – top (measured from the platform on which the appliance is installed)** | 79" | 79" |
* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites). |
||
** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual. |
Note to the consumer: There are various Government imposed Air Quality Regulations as well as Building Codes across Canada that have guidelines in regards to the installation of wood, pellet/biomass boilers. Before purchasing any of these products you should consult with your local building, bylaw departments as well as your home insurance company.