Max Caddy Hot Air Wood Furnace

By Caddy

No reviews yet Write a Review
$4,971.03
SKU:
PF01102
Width:
37.00 (in)
Height:
51.00 (in)
Depth:
61.00 (in)
Shipping:
Calculated at Checkout

Financing Available!

Quantity:

In Stock

Special Handling, Usually Ships within 7 business days
Adding to cart… The item has been added

***Only available in Canada***

Ingenuity 2.0

Thanks to its electronic platform facilitating connections between systems, PSG's largest furnace is the best option for your home heating and air conditioning system.

The power to communicate

Max Caddy’s new streamlined electronic platform makes it easy for different systems to talk to each other. Heat pumps, air conditioners, humidifiers-the Max Caddy easily communicates with all of these appliances using standard industry symbols and practices. Easy-to-identify input and output ports and a blower assembly with prewired main board simplify installation and hookup. And PSG’s touchscreen LCD control module makes input and output control a breeze. 

A benchmark for efficiency

The Max Caddy’s integrated control PC board and RTD probe automatically ensures that the furnace blower is operating at optimum speed, keeping the plenum at just the right temperature. The built-in heat exchanger system ensures that heat is transferred quickly and efficiently via the smoke ducts inside the furnace instead of being lost up the chimney. The result is superior comfort and energy efficiency, with savings of up to 30% on firewood.

 

Multi-energy flexibility and peace of mind

The Max Caddy can be installed as a wood-only unit, but is also available in wood+electric, wood+oil combo, or even wood+oil+electric triple combo configurations so you can heat your home using multiple energy sources. With Caddy series furnaces, you’ll always have an alternate source of heat to ensure the comfort and safety of your family.

Wood

Wood

This furnace can be installed as a wood-only unit. Blower box and fan limit kit required for this configuration.

 

Wood Electric

Combined Wood + Electric

This furnace can be installed as a wood+electric combo unit to ensure your central heating keeps running even when you’re not there to add more firewood. Electric element (fan limit kit included) required for this configuration.

 

Wood Fuel Oil

Combined Wood + Fuel Oil

This furnace can be installed as a wood+oil combo to ensure your central heating keeps running even when you’re not there to add more firewood. Oil burner unit and blocked vent switch required for this configuration.

 

Wood Add-on

If you’ve already got an oil, gas, or electric central heating system but want to add the flexibility of wood, the Max Caddy wood add-on furnace is for you. This unit, which installs on either side of your existing system, uses the same controls and fan as your existing furnace, giving you a fully compatible wood+oil, wood+gas, or wood+electric combo system.

 

Appliance performance (2)

Fuel type Dry cordwood (16" recommended)
Recommended heating area-ft² () 1,500 - 3,500
Overall firebox volume-ft³ 4.9
Maximum burn time () 17 h
Maximum input capacity (dry cordwood) (3) 421,000 BTU
Overall heat output rate < (4) 18,424 BTU/h (5.6 kW) to 66,576 BTU/h (19.6 kW)
Average overall efficiency (min. to max.) (5) 78.90% (HHV) (6) 85.8% (LHV) (7)
Delivered heat output rate (min. to max.) (8) 15,118 BTU/h (4.7 kW) to 51,241 BTU/h (16 kW)
Average delivered efficiency (min. to max.) (9) 64.80% (HHV) (6) 70.20% (LHV) (7)
Optimum efficiency (10) 85.80%
Average particulate emissions rate (1) (11) 0.753 lb/mmBTU (0.326 g/MJ)
Average CO (12) 12.20 lb/mmBTU (5.25 g/MJ)
Average electrical power consumption (13) 360 W

(1) Based on delivered heat output.

(2) Values are as measured per CSA B415.1-10, except for the recommended heating area, firebox volume, maximum burn time and maximum input capacity. Performances based on a fuel load prescribed by the standard at 10 lb/ft³ and with a moisture content between 18% and 28%.

(3) Input value at 10 lb/ft³ fuel loading density and dry energy value of 8,600 BTU/lb.

(4) Overall : Radiated and delivered heat together at 10 lb/ft³ fuel loading density over one total burn cycle.

(5) Efficiency based on radiated and delivered heat when allowing cycling from high to low burn to simulate thermostat demand.

(6) Higher Heating Value of the fuel.

(7) Lower Heating Value of the fuel.

(8) Delivered: Remotely provided to other rooms through ducting at 10 lb/ft³ fuel loading density over one total burn cycle.

(9) Efficiency based on delivered heat when allowing cycling from high to low burn to simulate thermostat demand. LHV % is based on manufacturer’s estimation.

(10) Optimum overall efficiency at a specific burn rate (LHV).

(11) This appliance is officially tested and certified by an independent agency.

(12) Carbon Monoxyde. Based on overall heat output at 10 lb/ft³ fuel loading density.

(13) Unless stated otherwise, measures were taken directly at the main power source and include all electrical components present in the appliance.

General features

High-efficiency certified appliance CSA B415.1-10
Maximum log length 25"
Log positioning Loading over depth
Chimney diameter 6"
Flue outlet diameter 6"
Type of chimney CAN/ULC S629, UL 103 HT (2100 °F)
Baffle type C-Cast or equivalent
Approved for a mobile home installation No
Shipping Weight 729 lb (331 kg)
Door type Single, glass with cast iron frame
Glass type Ceramic glass
Glass surface – dimensions (Width X Height) 14 1/2" X 10 1/8"
Glass air-wash system Yes
Blower (hp / speed / CFM) 1/2 / 4 / 2,100
Filter – dimensions (Width X Height X Depth) 16" X 20" X 1"
Overall dimension (Height) 50 1/2"
Overall dimension (Width) 36 1/4"
Overall dimension (Depth) 60 1/8"
Door opening – dimension (Height) 9 7/8"
Door opening - dimension (Width) 15 3/4"
Firebox – dimension (Height) 15 7/8"
Firebox – dimension (Width) 20 3/8"
Firebox – dimension (Depth) 26 1/4"
Firebox lined with refractory bricks for better heat distribution Yes
Stainless-steel secondary-air system improving gas combustion Yes
Adjustable threaded legs Yes
Steel thickness – body 3/16"
Steel thickness – top 1/4"
Easy-to-access ash drawer Yes
Air return plenum – dimension (Depth or Height) 17 7/8"
Air return plenum – dimension (Width) 19 7/8"
Hot air plenum – dimension (Depth or Height) 32 1/8"
Hot air plenum – dimension (Width) 25 3/8"
Burner – standard Beckett - AFG
Burner – other brand approved Riello
Burner – location Right or left
Burner – efficiency at input #1 85 % (Beckett)
Burner – efficiency at input #2 87 % (Riello)
Burner – recommended connector pipe diameter (Wood-oil) 7"
Burner – recommended exhaust pipe diameter 5"
Burner – location of exhaust pipe Right or left
Burner – capacity at input #1 90,000 BTU (26.4 kW)
Burner – capacity at input #2 91,000 BTU (27 kW)
Burner – orifice at input #1 0.55 X 60°W (Beckett)
Burner – orifice at input #2 0.50 X 70°W (Riello)
Burner – pump pressure at input #1 140 psi (Beckett)
Burner – pump pressure at input #2 150 psi / 165 psi
Electric element – location Right or left
Burner – recommended clearance for maintenance 24"
Electric element – recommended (maximum output) 20 kW
Electric element – other optional (maximum output) 25 kW
Water loop kit – connection location Right or left
Water loop kit – connecting pipe diameter 3/4"
Water loop kit – back-up tank volume 60 gal (227 L)
Canadian Standard (emissions) CSA B415.1-10
USA standard (safety) UL 1995, UL 727, UL 391
Canadian standard (safety) CSA B366.1, CSA C22.2 no 236, CAN/CSA B140.4 CSA B212-93
Tested and listed as per applicable standards By an accredited laboratory (CAN/USA)
Warranty Limited lifetime
Minimum clearances to combustibles*
(Data expressed in inches. 1 inch = 25.4 mm)
  Canada United-States
Clearance – back wall 24" 24"
Clearance – ducts <6'=6" + protection ; >6'=1" <6'=6" + protection ; >6'=1"
Clearance – recommended for maintenance on option side 24" 24"
Clearance – front 48" 48"
Clearance - side wall 6" 6"
Clearance – opposite side wall 24" 24"
Clearance – top (measured from the platform on which the appliance is installed)** 79" 79"

* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner's manual, catalogues, flyers, magazines and/or web sites).

** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.

Note to the consumer: There are various Government imposed Air Quality Regulations as well as Building Codes across Canada that have guidelines in regards to the installation of wood, pellet/biomass boilers. Before purchasing any of these products you should consult with your local building, bylaw departments as well as your home insurance company.